Distributors Stock

Part #84130104

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • DIN Rail Mountable Single Point Output Modules (35mm DIN)
  • UL and cUL Recognized, CE Compliant
  • Zero Voltage or Random Turn-On for AC Modules
  • 4kV Optical isolation with LED Indicator
  • AC Ratings 12-280 VAC, 5A. DC Output 5-60 VDC, 3A
  • Industry standard Color Coding Black (AC Output) Red (DC Output)
  • Barrier Strips Accept 14 to 28 AWG Wire.

Specifications

Part Number 84130105
Nominal Voltage [VDC] 4-32
Minimum Voltage [VDC] 4
Maximum Voltage [VDC] 32
Drop-out Voltage [VDC] 1.0
Maximum Current [mA] (1) 22
Resistance Current Regulated

Specifications apply to an ambient temperature of -30 to 80 °C unless otherwise noted.

(1) Modules are current limited +/- 10% at 25°C.

Part Number 84130105
Nominal Voltage [VDC] 4-32
Minimum Voltage [VDC] 4
Maximum Voltage [VDC] 32
Drop-out Voltage [VDC] 1.0
Maximum Current [mA] (1) 22
Resistance Current Regulated
Nominal Line Voltage 5-60 VDC
Minimum Line Voltage 5 VDC
Maximum Line Voltage 60 VDC
Max Off-State Voltage (2) 60 VDC
Max Off-State Leakage (3) 10 uA
Static Off-State dv/dt (4) 2.2 VDC
Maximum Rated On-State Current (5) N/A
Minimum On-State Current 10 mA
Max Surge Current (6) 5.0 A
On-State Voltage Drop or Resistance (7) 1.6 V
Maximum Turn-On Time [msec] (8) 0.05
Maximum Turn-Off Time [msec] (8) 0.05
Input/Output Isolation Voltage (9) 4000 Vrms
Input/Output Capacitance 4 pF
Operating Temperature Range -30 to 80°C
Storage Temperature Range -40 to 100°C
Line Frequency Range DC
Weight 1.1 oz. (31.2g)

Specifications apply to an ambient temperature of -30 to 80 °C unless otherwise noted.

(1) Modules are current limited +/- 10% at 25°C.

(2) Maximum 1 minute duration for AC modules when applied as a DC voltage rather than Peak AC voltage.

(3) At maximum line voltage, 25°C for AC modules and 80°C for DC module.

(4) Minimum dv/dt per EIA/NARM RS443, method RS397. dv/dt ratings do not apply to DC module.

(5) At 25°C, derate AC modules by 50 mA/°C to 80°C; derate DC module by 21.5mA/°C to 80°C.

(6) At 25°C, maximum duration: 1 AC cycle for AC modules, 1 second for DC module.

(7) At maximum rated on-state current and 25°C.

(8) At maximum line voltage, maximum rated output current, nominal input voltage, 25°C.

(9) At 25°C for 1 second maximum duration.