Ratings to 2A @ 280 VAC - SCR output - DC control - zero voltage (resistive loads) or instantaneous turn on (inductive loads) output.
Part #ASO242R
Contact us to request pricing, availability and customization options
Contact UsDescription | ASO241 | ASO242 |
Operating Voltage (47-63Hz) [Vrms] | 12-280 | 12-280 |
Transient Overvoltage [Vpk] | 600 | 600 |
Maximum Off-State Leakage Current @ Rated Voltage [mA] | 0.01 | 0.01 |
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] | 500 | 500 |
Maximum Load Current [Arms] | 1.5 | 2.0 |
Minimum Load Current [Arms] | 0.025 | 0.06 |
Maximum Surge Current (16.6ms) [Apk] | 40 | 120 |
Maximum On-State Voltage Drop @ Rated Current [Vpk] | 1.5 | 1.5 |
Minimum Power Factor (with Maximum Load) | 0.5 | 0.5 |
Description | Parameters |
Control Voltage Range | 4-10 VDC |
Must Turn On Voltage | 4.0 VDC |
Must Turn Off Voltage | 1.0 VDC |
Typical Input Current @ 5 VDC | 15 mAdc |
Nominal Input Impedance | 300 Ohm |
Maximum Turn-On Time [msec] | 1/2 Cycle |
Maximum Turn-Off Time [msec] | 1/2 Cycle |
Description | Parameters |
Dielectric Strength, Input/Output/Base (50/60Hz) | 2500 Vrms |
Minimum Insulation Resistance (@ 500 V DC) | 109 Ohms |
Maximum Capacitance, Input/Output | 8.0 pF |
Ambient Operating Temperature Range | -30ºC to 80ºC |
Ambient Storage Temperature Range | -30ºC to 125ºC |
Weight (typical) | 0.07 oz. (1.9g) |
Encapsulation | Thermally Conductive Epoxy |