Part #HS103DR-HD6090
Contact us to request pricing, availability and customization options
Contact UsPart Number | HS103DR-HD6090 |
Operating Voltage (47-63Hz) [Vrms] | 48-660 |
Transient Overvoltage [Vpk] | 1200 |
Maximum Off-State Leakage Current @ Rated Voltage [mArms] |
1.0 |
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] (2) |
500 |
Maximum Load Current [Arms] | 55 |
Minimum Load Current [Arms] | 150 |
Maximum Surge Current (16.6ms) [Apk] | 1200 |
Maximum On-State Voltage Drop @ Rated Current [Vac] |
1.15 |
Maximum I²t for Fusing (8.3 msec) [A² sec] | 6000 |
Minimum Power Factor (with Maximum Load) |
0.5 |
All parameters at 25°C unless otherwise specified.
(1) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Part Number | HS103DR-D2490 |
Control Voltage Range | 4-32 VDC |
Minimum Turn-On Voltage | 4.0 VDC |
Minimum Turn-Off Voltage | 1.0 VDC |
Maximum Reverse Voltage | -32 VDC |
Minimum Input Current | 7.0 mA |
Maximum Input Current | 12 mA |
Nominal Input Impeadance | Curent Regulated |
Maximum Turn-On Time [msec] | 1/2 Cycle |
Maximum Turn-Off Time [msec] | 1/2 Cycle |
All parameters at 25°C unless otherwise specified.
Description | HS103DR-Dxx90 |
Dielectric Strength, Input/Output/Base (50/60Hz) |
4000 Vrms |
Minimum Insulation Resistance (@ 500 V DC) |
10 9 Ohms |
Maximum Capacitance, Input/Output | 8 pF |
Ambient Operating Temperature Range | -40 to 80˚C |
Ambient Storage Temperature Range | -40 to 125˚C |
Status Indicator Display | None |
Weight (typical) | 1.36 lb. (619 g) |
Recommended Terminal Screw Torque Range: (in-lbs/Nm) |
6-32 Screws - 13-15/1.5-17. 8-32 Screws - 18-20/2-2.2. (Screws dry without grease) |
Thermal pad installed | Yes |