Distributors Stock

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • Hermetically seal rated to 175°C – Reduced risk of fire or meltdown in over current conditions
  • Backfilled with gas (primarily hydrogen) to effectively inhibit oxidation, resulting in low and stable contact resistance
  • Continuous current carry 150A at 85°C
  • Comply with IEC 60664-1 and RoHS standards

Applications

  • Material Handling
  • Residential ESS
  • DC Fast Charging

Specifications

Contact Arrangement1 Form A
Contact Resistance≤ 0.5 mΩ @ 200A
Rated Load Current150A (@ 50 mm2 wire)
Rated Switching Voltage750 VDC
Rated Switching Power112.5 kW
Min. Applicable Load6 VDC, 1A
Max. Switching Voltage750 VDC
Max. Switching Power112.5 kW (750 VDC)
Max. Breaking Current1500A (750 VDC), 1 cycle
SpecificationsData
Dielectric StrengthBetween Open Contacts3000 VAC, 1 min
Between Coil & Contacts4000 VAC, 1 min
Insulation Resistance1000 MΩ at 1000 VDC
Operate Time (at nomi. volt.)≤ 30ms
Release Time (at nomi. volt.)≤ 10ms
Vibration Resistance (sine)10 Hz - 500 Hz, 49 m/s2
Shock ResistanceFunctional Open: 196 m/s2
Functional Close: 490 m/s2
Destructive: 490 m/s2
Ambient Temperature-40°C - 85°C
Humidity5% RH - 85% RH
TerminationM6 female screw
MountingM5 screw
Unit WeightApprox. 270 g
Outline Dimensions76.5mm x 39mm x 70mm
Nominal Voltage (VDC)Pick-up Voltage (VDC)Drop-out Voltage (VDC)Coil Power (W)
12≤ 9≥ 1∼6.0 @ 23°C
24≤ 18≥ 1
SpecificationsData
Electrical EnduranceCapacitive LoadSwitch on: 2 x 104 cycles (37.5 VDC, C = 1100 uF, inrush 400 A. Steady 150 A)
Resistive LoadSwitch: 500 cycles (750 VDC, 150 A)
Switch: 1000 cycles (450 VDC, 150 A)
Current Endurance150 A, cont.
180 A, 2h
225 A, 15 min
320 A, 2 min
400 A, 1 min
600 A, 20 s
900 A. 20 s
Mechanical Endurance2 x 105 cycles, on-off ratio: 0.5 s : 0.5 s