Distributors Stock

Part #H12D4875

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • Ratings from 25A to 125A @ 48-530 VAC
  • Snubber Included
  • SCR output for heavy industrial loads
  • Zero Voltage or instantaneous turn-on outputs
  • UL/CSA/VDE Approved, CE Compliant to EN60950-1
  • Improved SEMS screw and washer
  • Redesigned housing with anti-rotation barriers
  • DC control
  • Direct bond copper substrate
  • EMC Compliant to Level 3
  • Direct power lead frame
  • Epoxy free design

Specifications

Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms
Minimum Insulation Resistance (@ 500 VDC) 109 Ohm
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range -40 to 80 °C
Ambient Storage Temperature Range -40 to 125 °C
Weight (typical) 2.6 oz (74.9 g)
Housing Material UL94 V-0
Baseplate Material Aluminum
Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7
Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2
SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2.0-2.2
Input/Load Terminal Screw Torque Range (in-lb/Nm) w/”K” option 8-10 / 0.9-1.13
Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC
Humidity per IEC60068-2-78 93% non-condensing
LED Input Status Indicator w/”G” option (green)
MTBF (Mean Time Between Failures) at 40°C ambient temperature 11,641,553 hours (1,328 years)
MTBF (Mean Time Between Failures) at 60°C ambient temperature 7,210,376 hours (823 years)
  • EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
  • Designed in accordance with the requirements of IEC 62314
  • IEC61000-4-2 : Electrostatic Discharge – Level 3
  • IEC61000-4-4 : Electrically Fast Transients – Level 3
  • IEC61000-4-5 : Electrical Surges – Level 3
  • IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitude over 10-55 Hz
  • IEC 60068-2-27 : Shock Resistance 15g/11ms