Distributors Stock

Part #PTE7300-14AM-1B016SN

Need more information?

Contact us to request pricing, availability and customization options

Contact Us

Features

  • Cyclical Redundancy Check (CRC) assures you that communications and data are reliable.
  • Pressure ranges from 0-16 bar to 0-600 bar (0-230 to 0-8700 psi)
  • Best in class accuracy and fast response time to meet the highest performance applications
  • Digital pressure output and I2C bus for connecting multiple devices
  • Low power consumption to optimize energy efficiency
  • High Resistance to Electromagnetic Noise (EMC)
  • Stainless steel, fully hermetic, IP69K sensor package and hermetic port modules available to meet the harshest environments
  • Snubber option for dampening of pressure spikes due to hammer and cavitation
  • REACH/RoHS/CE compliant

Specifications

Pressure Ranges 0-16 bar to 0-600 bar (0-230 psi to 0-8700 psi)
Pressure Reference Gauge (Module) and Sealed Gauge (fully hermetic sensor)
Supply Voltage 2.7 VDC to 5.5 VDC
Digital Interface I2C with CRC (memory integrity, and data transmission)
Device Address 0xDA (including CRC)
0x6C (excluding CRC)
Operating Current In Sleep Mode 6.5 uA (typical)
Operating Current In Active Mode 3.7mA typical (4mA maximum)
Available Data Pressure (int16)
Bridge temperature (int16)
Status (int16)
Device serial (int32)
Resolution 13 bit
Response Time (12 bit) < 1 ms
Probe Configurations On-demand, single cycle
Recommended pull-up resistors 1kOhm to 10kOhm, depending on cable length
External Capacitive Load for I2C Bus Line 400 pF max (depends on the cable length)
ESD ±4KV Contact;
±8KV Air
Radiated Immunity 80-1000MHz 3V/m
1400-2000MHz 3V/m
2000-2700MHz 1V/m
Conducted Immunity 0.15-80MHz 3Vrms
Magnetic Immunity 3 A/m for 5 minutes
Proof Pressure 2.5X full scale pressure
Burst Pressure 5X full scale pressure
Vibration IEC 60068-2-6 with 2.0mm displacement, Sensor: 30g (10...2000Hz); Module: 20g (10...2000Hz)
Mechanical Shock IEC 60068-2-27, 50g min, (Module); IEC 60068-2-27, 500g min (fully hermetic sensor)
Drop (any Axis) 1m
Water Hammer 1.6X full scale pressure for 100k cycles, 1.3xFS for 200k cycles
Ingress Protection IP00 (Module), IP69K (fully hermetic sensor)
Media Compatibility Fluids and Gases compatible with 17-4PH stainless steel
Pressure (Best Fit Straight) ±0.25% FS @ 25°C
Pressure (Total Error Band) +/-1.5%FS @-20° to 85°C
Operating Endurance >10M cycles
Operating Ambient Temperature -40° to +100°C
Operating Media Temperature -40° to +125°C
Storage Temperature -40° to +125°C
Series Pressure Port Electrical Connector External Sealing Output Type Pressure Range Pressure Reference Snubber
PTE7300 A: G1/4A DIN 3852-E
B: 1/4-19PT (R1/4)
C: 7/16-20 UNF-2A (MALE)
D: 1/4-18NPT E: 7/16-20 UNF-2B (FEMALE)
M: M12 5-pin glass-to-metal-seal (sensor only)
N: 5x1 2mm pitch pin to header (module only)
0: No sealing ring
1: FKM (Viton) sealing ring (only for G1/4A pressure port)
2: HNBR sealing ring (only for 7/16-20 UNF-2A MALE pressure port)
B: I 2 C (12 ENOB + CRC) 016: 0-16bar
050: 0-50bar
100: 0-100bar
200: 0-200bar
250: 0-250bar
350: 0-350bar
400: 0-400bar
500: 0-500bar (sensor only)
600: 0-600bar (sensor only)
S: Sealed gauge (M12 5-pin only)
B: Gauge (module only)
N: No snubber
S: Snubber with 0.5 damping hole

Related Resources