Features

  • Ratings from 60 A to 100 A @ 100 VDC
  • Mosfet Output
  • UL Approved, CE Compliant to EN60950-1
  • Improved SEMS screw and washer
  • Redesigned housing with anti-rotation barriers
  • DC control
  • EMC Compliant to Level 3
  • Epoxy Free Design

Specifications

Description 7 A 12 A 20 A
Recommended Operating Voltage [Vdc] 1-72 1-72 1-72
Absolute Maximum Rating [Vdc] 100 100 100
Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3
Maximum Load Current [Adc] 60 80 100
Minimum Load Current [mA] 5 5 5
Maximum Surge Current (10msec) [Adc] 180 220 330
Maximum On-State Voltage Drop @ Rated Current [Vdc] 0.6 0.7 0.5
Maximum On-State Resistance [RDS-ON] [Ohms] 0.01 0.008 0.005
Thermal Resistance Junction to Case (Rjc) [°C/W] 0.34 0.34 0.27
Minimum Heat Sink for Rated Current @ 40°C [°C/W] 1 0.5 0.5
Maximum Pulse Width Modulation Frequency [Hz] 1000 900 800

 

Description DC Control
Control Voltage Range 3.5-32 VDC
Maximum Reverse Voltage -32 VDC
Minimum Turn-On Voltage 3.5 VDC
Must Turn-Off Voltage 1 VDC
Minimum Input Current (for on-state) 10 mA
Maximum Input Current 15 mA
Nominal Input Impedance Current Regulated
Maximum Turn-On Time [μsec] 100
Maximum Turn-Off Time [μsec] 100

 

Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 3750 Vrms
Minimum Insulation Resistance (@ 500 VDC) 109 Ohms
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range -40 to 100 °C
Ambient Storage Temperature Range -40 to 125 °C
Weight (typical) 2.66 oz (75.5 g)
Housing Material UL94 V-0
Baseplate Material Aluminum
Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7
Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2
Input/Load Terminal Screw Torque Range (in-lb/Nm) w/”K” option 8-10 / 0.9-1.13
Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC
Humidity per IEC60068-2-78 93% non-condensing
MTBF (Mean Time Between Failures) at 40°C ambient temperature 21,395,130 hours (2,441 years)
MTBF (Mean Time Between Failures) at 60°C ambient temperature 11,545,504 hours (1,317 years)