  • Dual Axis Measurement Range up to ±60°
  • Option for a Single Axis Measurement Range of 360°
  • High Resolution: 0.01°
  • High Accuracy: 0.1°
  • Glass Fiber Reinforced Plastic Housing available
  • Factory Calibrated Linearity
  • Temperature Compensated for Bias and Sensitivity
  • Interface: CANopen
  • Highest Protection Class: IP69K, IP68

Specifications

Model T- M2 (or P2)- (Range) T-M1 (or P1) - 360
15 30 60  
Measurement Range ± 15° ± 30° ± 60 360°
Number of Axes 2 (Standard), 1 optional 1
Resolution 0.01°
Accuracy (T = -10 °C to +40 °C) 0.1°
Sensor Response Time 10 ms (Without Filter)
Recommended Measurement Rate Up to 10 Hz
Interface CANopen (In Conformance to DS410)
Transceiver According ISO 11898,
Galvanically Isolated by Opto-Couplers
Transmission Rate Adjustable: Max. 1 MBaud
(Factory Setting : 125 kBaud)
Addressing Programmable Node-id from 1 to 127 (Factory Setting: 1)
Supply Voltage 10 to 30 V DC (Absolute Maximum Ratings)
Current Consumption Max. 57 mA at 10 V DC; Max. 53 mA at 24 V DC
EMC Emitted Interference: EN 61000-6-4
Current Consumption Noise Immunity: EN 61000-6-2
Connector Cable 5 Pin M5 male (A-coded)
Ø 7.1 mm [0.28 in] Polyurethane: 4 x 2 x 0.34 mm2 [AWG 22]
Housing Material (Plastic) Glass Fiber Reinforced PBT (Polybutylene Terephthalate)
Housing Material (Metal) AW6082 Corrosion resistant Aluminum alloy, passivated
Potting Material PUR (Polyurethane)
Shock (EN 60068-2-27)2 ≤ 100 g (half sine, 6 ms)
Vibration (EN 60068-2-6)2 1.5mm (10 to 58 Hz) & ≤ 20 g (58 to 2000 Hz)
Weight 170 gm / 6 oz
Operating Temperature -40 °C to +85 °C / -40 °F to 185 °F
Humidity 98 % Relative Humidity, Non-Condensing
Protection Class (EN 60529) IP 69K (With Appropriate Mating Connector and mounting), IP68, IP67